NEURO-AUDIO ALL-IN-ONE

DESCRIPTION

 
All-in-one Solution for ABR, ASSR, Multi-ASSR, MLR, LLR/CAEP, TEOAE, DPOAE, SOAE, ECochG, VEMP, P300, MMN and Other Tests

 
A full range of objective and subjective techniques for the diagnostics of acoustic and vestibular analyzer affection, hearing threshold search is in one small unit now! Using this device you can perform ABR, ASSR, multi-ASSR, MLR, LLR/CAEP, TEOAE, DPOAE, SOAE, ECochG, VEMP, P300, MMN, pure tone audiometry techniques easily.

 
Automatic Multi-ASSR Test

 
Multi-ASSR test implemented in Neuro-Audio system allows minimizing test duration due to automatization (intensity switching for hearing threshold search), stimulation of both ears simultaneously using 8 carrier frequencies (4 in each ear, from 500 Hz to 4000 Hz, ), use of frequency-specific Chirp stimulus which takes into account the cochlear anatomy for the response amplitude increase. Test result is represented as estimated pure tone audiogram used further for hearing aid fitting.

 
High Acquisition Quality

 
Well-considered system characteristics (low level of amplifier noise) and software features (adaptive notch filter, weighted averaging, Chirp stimulus, calculation of statistical parameters of signal and noise, up-to-date algorithms for automatic response detection) help a physician to obtain a high-quality record quickly. All tests can be performed when patient is awake (not-sedated).

 
VEMP with Biofeedback

 
Neuro-Audio system ensures full state-of-the-art support of VEMP tests, including VEMP with biofeedback, VEMP amplitude correction by mean EMG activity level, and also a unique function of EMG histogram with the possibility of post-hoc analysis (important for children). Acquisition of bone-conduction VEMP is also possible using bone vibrator amplifier (separate unit) and B-71 bone vibrator. Supported technique variants: cVEMP (cervical), oVEMP (ocular), gVEMP (galvanic).

 
New Standard for Routine Tests

 
Modern interface, powerful database, configurable normal values, high quality of obtained records and reproducible results allow user to solve a wide range of daily audiological problems with highest accuracy. Variety of built-in test templates helps you to start working with program, and the possibility of their adjustment makes it possible to set up all the templates for your own requirements. Due to these unique features Neuro-Audio system manufactured by Neurosoft can be used both in hospitals and research institutes.
 
 
The support of HL7 standard allows integrating all diagnostic Neurosoft systems into the information system of a healthcare facility.
2-channel device for conducting objective audiometry (ABR)
EQUIPMENT



Neuro-Audio electronic unit
1 PC.
Auditory stimulator , (headphones) TDH-39 (2×6.3 mono, shielded)
1 PC.
Assembled holder H-1S
1 PC.
Electrode adhesive paste TEN20 114 g.
1 PC.
Holder mount
1 PC.
Abrasive paste for skin preparation Everi , 160 g.
1 PC.
OAE-02-2 probe
1 PC.
Medical tape Transpore
1 PC.
OAE probe tip
1 PC.
Technical Manual "Neuro-Audio"
1 PC.
Set of eartips , adult, 3-14 mm diameter
1 PC.
User manual "Neuro-Audio.NET"
1 PC.
Set of eartips , adult, 3-14 mm diameter
1 PC.
Guidelines "OAE Probes OAE-02, OAE-03, OAE-04 and aScreen Probe"
1 PC.
Probe tip extractor
1 PC.
Calibration Guidelines "Neuro-Audio"
1 PC.
Test cavity
1 PC.
Guidelines "EABR Test"
1 PC.
Cup electrode with cable , 5 pcs., 1 m
1 PC.
Guidelines "VEMP: Vestibular Evoked Myogenic Potential"
1 PC.
Y-adapter
1 PC.
Guidelines "How to get quality ABR and ASSR recordings"
1 PC.
Adapter for 2-channel EP recording
1 PC.
Package set
1 PC.
Disposable ECG electrode F9049 22x34 mm, Fiab, Italy
1 PC.
License for the use of software "Neuro-Audio.NET" with additional software module "Neuro-Audio.NET/VEMP"License for the use of software "Neuro-Audio.NET" with additional software module "Neuro-Audio.NET/VEMP"
1 PC.
Cable for disposable electrode with Alligator clip and touch-proof connector, white, 1 m
1 PC.
License for the use of software "Neuro-Audio.NET" with additional software module "Neuro-Audio.NET/OAE"
1 PC.
Cable for disposable electrode with Alligator clip and touch-proof connector , red, 1 m
1 PC.
License for the use of software   "Neuro-Audio.NET" with additional software module   "Neuro-Audio.NET/ABR"
1 PC.
Cable for disposable electrode with Alligator clip and touch-proof connector , black, 1 m



Cable for disposable electrode: “Alligator” clip - touch-proof, blue, 1 m